>

Synthes rfna surgical technique - Total Hip System. With more than 2 million stems 1 provided for patients worldwide and thi

Do you find yourself in arguments with someone who uses narcissistic tactics? It helps to

2 Surgical Technique • Variable Angle Locking Hand System The DePuy Synthes Variable Angle Locking Hand System consists of plates that are anatomic, procedure-specific, and available in both stainless steel and titanium. The Variable Angle Locking Hand System offers instrumentation to aid in:2 DELTA XTEND™ Reverse Shoulder System • Surgical Technique DELTA XTEND™ Reverse Shoulder System • Surgical Technique 3 Key Surgical Steps Humeral Surgical Steps Superior-lateral Approach 3. Proximal reaming guide positioning 1. Approach 2. Humeral head resection Modular Implant Cementless Technique Monobloc Implant …Starting a conversation with a complete stranger can be a little intimidating, and sometimes you don't know what to say. Use the FORD technique the next time you meet someone to av...TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges with intramedullary ...TM System Surgical Technique DePuy Synthes 5 Step 1 OR Set-Up Precautions: It is recommended to use a Jackson Table to assist in achieving the proper patient positioning and an unrestricted fluoroscopic view. Confirm the C-Arm will allow for easy rotation in the lateral, oblique, and A/P positions around the table.The RFN-ADVANCED™ System is a retrograde femoral nailing system designed to improve fixation for distal femur fractures 1. As part of the Advanced Nailing System, it is designed to address simple to complex trauma cases 2 with increased fixation and stability. 1,3. Product Specifications. How to Use This Product.2 Surgical Technique • LCP Compact Hand Low profile plates and fully countersunk screws Anatomically contoured Rotation Correction Plate LCP combi-hole Facilitates intraoperative inspection of the reduction and correction of the rotational axis. Intraoperative choice wbet eenc omonsiesp r and locking holes. LCP Compact Handmarrow for any surgical procedures that require bone graft to facilitate fusion and/or fill bone defects. These procedures include spinal fusion, joint arthrodesis, total joint replacement, fracture repair, nonunion, maxillofacial reconstruction, and tumor removal 4 Synthes Reamer/Irrigator/Aspirator (RIA) Technique Guidesynthes.vo.llnwd.netThe Modular Mini Fragment LCP™ System is an instrument and implant module set intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. Product Specifications. How to Use This Product.Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Synthes GmbH Luzernstrasse 21 4528 Zuchwil, Switzerland EU +800-88882020 EU +32 2 4037222 Note: For recognized manufacturer, refer to the product label. Please refer to the instructions for use for a complete list of indications,back of this surgical technique and the package insert is available on the website listed . Indications Metacarpophalangeal Joint Implant Arthroplasty Rheumatoid or post-traumatic disabilities with: • Fixed or Stiff MP Joints • X-Ray Evidence of Joint Destruction or Subluxation • Ulnar Drift, Noncorrectable By Surgery of Soft Tissues AloneThe SIGMA™ Knee System offers one of today's most comprehensive, integrated knee systems. Based on the clinically successful P.F.C. Total Knee System, the SIGMA Knee continues a history on innovation based on clinical evidence. The SIGMA™ Knee embraces a wide variety of surgeon philosophies and surgical techniques, while providing ...Figure 3 Clear Out Reamer RECLAIM Revision Hip System Surgical Technique DePuy Synthes Joint Reconstru . Open the catalog to page 7. PROGRESSIVE DISTAL REAMING RECLAIM Distal Stem implants are available in four different lengths and in 1 mm diameter increments ranging from 14 mm to 27 mm, 29 mm and 31 mm diameters. Straight Stems are available ...SE_793149 AA page 2 / 5 Instructions for Use Retrograde Femoral Nail Advanced Devices in scope Retrograde Femoral Nail Advanced, 5 Degree Bend LengthThe SIGMA™ Knee System offers one of today's most comprehensive, integrated knee systems. Based on the clinically successful P.F.C. Total Knee System, the SIGMA Knee continues a history on innovation based on clinical evidence. The SIGMA™ Knee embraces a wide variety of surgeon philosophies and surgical techniques, while providing ...18 Synthes PFNA Surgical Technique 4 Insertion of the PFNA Use image intensifier control to insert the PFNA. Carefully insert the PFNA manually as far as possible into the femoral opening. Slight twisting hand movements help inser-tion. If the PFNA cannot be inserted, select a smaller size PFNA diameter or ream the medullary cavity to a diameter …2 DePuy Synthes Surgical Technique MatrixMIDFACE™ Plate and Screw System MatrixMIDFACE Plate and Screw System Description The DePuy Synthes MatrixMIDFACE Plate and Screw Sys-tem consists of a variety of plates and meshes that come in multiple shapes and sizes to meet the anatomical needs of the patient. This system is designed for use with theRIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3 Indications The DePuy Synthes RIA 2 System is intended for use in adults and adolescents (12-21 years) • To clear the medullary canal of the bone marrow and debris • To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis6 DePuySynthes OPAL™ Spacer System Surgical Technique 1. Determine implant size Option A: Insert and rotate technique Instruments 03.803.011– Trial Implant OPAL, 03.803.015 size 11 mm–15 mm Precaution: The insert and rotate technique can only be used for sizes 10 mm–15 mm. For all other sizes, use the impact technique.SE_793148 AC page 2 / 7 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)Pre-drill the hole for a 1.5 mm cortex screw with the 1.1 mm drill bit using the double drill guide. To drill a gliding hole, use the 1.5 mm drill bit with the double drill guide. (1) To adjust the plate position, a 1.5 mm cortex screw can be inserted in the non-threaded elongated hole (in T-, Y- and Condylar Plate).Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packaging. Prior to steam-sterilization, place the product in an approved wrap or container. Follow the cleaning and sterilization instruction given by the Synthes brochure "Important ...Femoral Neck System (FNS) Surgical Technique DePuy Synthes 1 The Femoral Neck System (FNS) is a dedicated product for the fi xation of femoral neck fractures and offers the following features: System Highlights 3. DePuy Synthes Report: Static Cut Through Rotation Test in Bone Foam. 2017. Ref: 0000165855.* 4.4 Surgical Technique • LCP Olecranon Plate 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.4 DePuySynthes 3.5 mm LCP ® Medial Distal Tibia Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which14 DePuy Synthes PHILOS and PHILOS Long Surgical Technique 5 Drill the lateral cortex and determine proximal screw length 5a Technique for osteoporotic bone: The following technique describes screw depth measur-ing optimized for osteoporotic bone. In good bone stock, change to options A or B for drilling the screw hole and depth measuring.The DePuy Synthes Variable Angle Locking Patella Plating System is indicated for the fixation and stabilization of patellar fractures in normal and osteopenic bone in skeletally mature patients. Contraindications. No contraindication specific to these devices. 2.4/2.7 mm Variable Angle Locking Lateral Rim Patella Plates • Surgical Technique 53.5 mm LCP® Olecranon Plates Surgical Technique DePuy Synthes 13 2 Fixation with 3.5 mm locking screws Instruments 310.288 2.8 mm Drill Bit, quick coupling 312.648 2.8 mm Threaded Drill Guide 314.115 StarDrive Screwdriver, T15 314.116 StarDrive Screwdriver Shaft, T15 319.01 Depth Gauge 511.770* Torque Limiting Attachment, 1.5 Nm or 511.773 …mandatory to consult the corresponding Surgical Technique Guide (www.synthes. com/lit) of the product system being used. Combination of medical devices Synthes has not tested compatibility with devices provided by other manufacturers and assumes no liability in such instances. Magnetic Resonance environment CAUTION:The Modular Mini Fragment LCP™ System is an instrument and implant module set intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. Product Specifications. How to Use This Product.Ramit Sethi is a New York Times best-selling author and creator of one of our favorite personal finance sites, I Will Teach You to Be Rich. In his weekly video Q&A for Lifehacker, ...3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15.The Arthrex Femoral Nail System is targeted for use in intramedullary fixation of fractures of the femur. Consisting of antegrade and retrograde femoral opti...Better fixation on the shaft allows for minimally invasive approach. LCP combi-holes. Tapered end. Undercuts. Barrel angle 130°–150°. 1 to 20 holes. Barrel length: 25 and 38 mm. Thickness 5.8 mm. Fixation with locking screws 5.0 mm, cortex screws.Learn the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) surgical technique with step by select instructions on OrthOracle. Their e-learning platform contains high resolution images and adenine certified CME of the Femoral cheat fracture: Fixation at Depuy-Synthes Expert retrograde/antegrade ...This surgical technique guide alone does not provide suficient background for direct use of the ... DePuy Synthes StarDrive vs Hex Static Torsion Test. 2011. #SET_20110610. Screw Reference Chart Thread Diameter 2.7 mm 3.5 mm 4.0 mm Screw Type Cortex Locking Cancellous Drill Bit forPlease read these instructions for use, the Synthes brochure"Important Informa-tion" carefully before use. Ensure that you are familiar with the appropriate surgical technique. Plate and Screw Implants consist of various plates and screws to be implanted which are single packed, and available non-sterile and/or sterile (corresponding16 Synthes PFNA Surgical Technique Surgical Technique 1 Determination of PFNA entry point and guide wire inser-tion In AP view, the PFNA entry point is usually on the tip or slightly lateralto the tip of the greater trochanter in the 6° curved extension of the medullary cavity, as the ML angle of the PFNA is 6°.Ensure that you are familiar with the appropriate surgical technique. External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments.Surgical Technique GLOBAL UNITE™ Platform Shoulder System Anatomic and Reverse DePuy Synthes 7 Key Surgical Steps: Reverse REVERSE 4. Metaglene Impaction 5. Inferior and Superior Locking Screw Fixation 6. Anterior and Posterior Spherical Head Screw Fixation 7. Glenosphere Implantation Glenoid Surgical Steps 5. Proximal Humeral Reaming 6.Distal: 9-12 mm, in 1-mm-Abstufungen (kurze Nägel) 9, 10, 12, 14 mm (lange Nägel) Kurze Nägel: 170 mm extrakurz 200 mm kurz 240 mm (ein Nagel passend für links und rechts) Lange Nägel: 300 mm-420 mm (linke und rechte Nägel, in 20-mm-Abstufungen) CCD-Winkel 125° und 130° Zusätzlich 135° für Nägel, Länge 240 mm.Pre-drill the hole for a 1.5 mm cortex screw with the 1.1 mm drill bit using the double drill guide. To drill a gliding hole, use the 1.5 mm drill bit with the double drill guide. (1) To adjust the plate position, a 1.5 mm cortex screw can be inserted in the non-threaded elongated hole (in T-, Y- and Condylar Plate).DePuy Synthes Joint Reconstruction Revision Solutions offers both surgeons and patients a comprehensive portfolio of products for managing the many challenges of total joint arthroplasty. The DePuy Synthes Joint Reconstruction LPS (Limb Preservation System) is designed with these considerations in mind to allow for versatility in such difficult ...Plantar fasciitis is a common condition of heel pain with a lifetime incidence up to 10%. For this entity, conservative treatment is considered the gold standard, involving non-steroidal anti-inflammatory drugs, stretching exercises of the plantar fascia, activity modifications, ice, and insoles. When patients do not respond to these treatments, partial or total plantar fascia release has been ...2 DePuy Synthes Joint Reconstruction CORAIL Upgrade Kit Surgical Technique Surgical Technique Step 1: Pre-Operative Planning The CORAIL Hip System provides pre-operative templates at three different magnifications (100%, 115% and 120%). The templates are placed over the AP and lateral radiographs to help determine the implant size in12 Surgical Technique • TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) - Screw Only 3b. Optional technique: Open canal Optional instruments 03.037.004(S) 16 mm Cannulated Hollow Drill Bit 03.037.104(S) 1 6 mm Cann Percutaneous Hollow Drill Bit Ensure the centering mechanism is in the correct position prior to using the hollow drill bit.Please read these instructions for use, the Synthes brochure "Important Information" and the corresponding surgical technique Compact Midface (DSEM/CMF/0316/0121) carefully before use. The Compact Midface, Orbital plates, and Orthogmathic Systems offer a wide range of different sizes, lengths, and thickness of plates and screws implants. AllSternal ZIPFIX® System Surgical Technique DePuy Synthes 7 Mission The AO's mission is promoting excellence in patient care and outcomes in trauma and musculoskeletal disorders. THE AO PRINCIPLES OF FRACTURE MANAGEMENT 4 Müller ME, M Allgöwer, R Schneider, H Willenegger. Manual of Internal Fixation.Femoral Neck System (FNS) Surgical Technique DePuy Synthes 14 3. Determine length Instrument 03.168.003 Direct Measuring Device for 3.2 mm Guide Wires Slide the direct measuring device over the central guide wire. (1) Read the depth of the guide wire on the direct measuring device. (2) As the guide wire is inserted into the subchondral bone (in …Synthes 5 Surgical Technique—DHS 2. P. Regazzoni, Th. Rüedi, R. Winquist, and M. Allgöwer. The Dynamic Hip Screw Implant System. Berlin: Springer-Verlag, 1985. 5. 38 mm barrel 25 mm barrel Plate selection Barrel length The standard 38 mm barrel length is most commonly indicated. The 25 mm short barrel is indicated for specific clinical situations, …Femoral Neck System (FNS) Surgical Technique DePuy Synthes 14 3. Determine length Instrument 03.168.003 Direct Measuring Device for 3.2 mm Guide Wires Slide the direct measuring device over the central guide wire. (1) Read the depth of the guide wire on the direct measuring device. (2) As the guide wire is inserted into the subchondral bone (in …Femoral Neck System. The Femoral Neck System (FNS) is engineered for femoral neck fractures.1. Regardless of construct size, FNS offers enhanced rotational stability. Mechanical testing indicates up to 40% increased rotational stability when comparing to a sliding hip screw (SHS).2,4. Get in Touch with a Sales Consultant.Please read these instructions for use, the Synthes brochure “Important Informa-tion” and the corresponding surgical techniques carefully before use. Ensure that you are familiar with the appropriate surgical technique. Material Material: Standard: PEEK (Polyetherether-ketone) ASTM F 2026 TAN (Ti-6Al-7Nb) ISO 5832-11 Intended useLearn the Femoral neck fracture: Proximal femoral nail (Synthes long TFNA) for Intertrochanteric fracture surgical technique with step by step instructions on OrthOracle. Our e-learning platform contains high resolution images and a certified CME of the Femoral neck fracture: Proximal femoral nail (Synthes long TFNA) for Intertrochanteric ...Synthes Rfna Technique Guide ... PDF Surgical Technique Synthes vo llnwdsynthes vo llnwd o16. Synthes 03 616 021 Konstellation Verschlusskappe Treiber Pangea.Care and Maintenance of Synthes Instruments", Article No. 035.000.090. Table of Contents Image intensifier control Introduction Product Information Surgical Technique Overview 2 AO ASIF Principles 4 Indications and Contraindications 5 Implants/Set 6 Instruments 7 Preoperative Planning 8 Patient Positioning and Approach 9 Surgical Technique 10Learn the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) surgical technique with step by select instructions on OrthOracle. Their e-learning platform contains high resolution images and adenine certified CME of the Femoral cheat fracture: Fixation at Depuy-Synthes Expert retrograde/antegrade ...pull traction at 30° angle over triangle for reduction. Reaming. ream 1.5mm above size of final nail. Nail Insertion. insert nail over guidewire. Interlocking Screws. targeting guide to place distal interlocking screws first. check femoral neck, get perfect circles of proximal interlocking screws and insert.14 DePuy Synthes PHILOS and PHILOS Long Surgical Technique 5 Drill the lateral cortex and determine proximal screw length 5a Technique for osteoporotic bone: The following technique describes screw depth measur-ing optimized for osteoporotic bone. In good bone stock, change to options A or B for drilling the screw hole and depth measuring.DePuy Synthes test result summary for Secure Retaining Screws. 09/30/2020. Windchill Document #0000295306 2. DePuy Synthes RFNA Locking Polymer Rationale. …Remove the drill bit and drill guide. Insert the appropriate length locking screw into the bone with power, using the 1.5 Nm Torque Limiting Attachment (TLA) (511.770 or 511.773) and Stardrive or Hexagonal Screwdriver Shaft (314.116 or 314.030). Warning: Always use the TLA when using power.TFN – Titanium Trochanteric Fixation Nail System Technique Guide Synthes... Page 16 Insert the guide wire through the protection sleeve and drill sleeve. Confirm guide wire placement in both the AP and lateral planes. Insert to a depth of approximately 15 cm. Re- move the drill sleeve.SE_793149 AC page 3 / 5 3.5 mm VA Locking Screws* Article No. Length (mm) Article No. Length (mm) 02.127.110 10 02.127.144 44 02.127.112 12 02.127.146 46Search in Depuy Synthes catalogs and technical brochures on MedicalExpo and find the information you need in 1 click. Exhibit with us {{>currencyLabel}} Back ... DESIGN RATIONALE AND SURGICAL TECHNIQUE. 28 Pages. PRODUCT RATIONALE AND SURGICAL TECHNIQUE. 32 Pages. Speed. 2 Pages. attune. 80 Pages. HAMMERLOCK® 2. 2 Pages. DePuy Glenoid ...The R/AFN is a cannulated intramedullary nailing system for the treatment of fractures of the distal femur and/or diaphyseal fractures in which a retrograde approach is indicated. …12 Surgical Technique • TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) - Screw Only 3b. Optional technique: Open canal Optional instruments 03.037.004(S) 16 mm Cannulated Hollow Drill Bit 03.037.104(S) 1 6 mm Cann Percutaneous Hollow Drill Bit Ensure the centering mechanism is in the correct position prior to using the hollow drill bit.4 DePuy Synthes TFNA – Proximal Femoral Nailing System Surgical Technique AO Principles 1 Müller ME, Allgöwer M, Schneider R, Willenegger H (1995) Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg, New York: Springer 1991. 2 Rüedi TP, RE Buckley, CG Moran. AO Principles of Fracture Management. 2nd ed. Stuttgart, New York: Thieme. 2007.You can read something and hope that it’ll all be beamed into your brain for future application. Or you can read it and write down what you just learned, as if you were teaching s...Remove gross soil using a soft-bristled brush or soft, lint-free cloth. 2. Manually clean device for a minimum of two minutes in a freshly prepared neutral or mild alkaline detergent solution. Follow the detergent manufacturer’s instructions for the correct dilution, temperature, water quality and exposure time.RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3 Indications The DePuy Synthes RIA 2 System is intended for use in adults and adolescents (12-21 years) • To clear the medullary canal of the bone marrow and debris • To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesisWith more implant designs and choices than any competitive system, you won't have to compromise when meeting the individual needs of patients. Revision Deep Profile 54-72 mm DePuy Synthes Design Rationale and Surgical Technique. KEY BONE STOCK AND LANDMARK CONSIDERATIONS Radiographic landmarks are helpful in assessing the acetabular bone stock.9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared Instrumentation TFNA-FRN A.7. 2/8/2018. Windchill Document #0000273347. 11. DePuy Synthes Design Verification Report – T115 FRNProtection Tube – Bending Resistance. 10/13/2017.Synthes 5 Surgical Technique—DHS 2. P. Regazzoni, Th. Rüedi, R. Winquist, and M. Allgöwer. The Dynamic Hip Screw Implant System. Berlin: Springer-Verlag, 1985. 5. 38 mm barrel 25 mm barrel Plate selection Barrel length The standard 38 mm barrel length is most commonly indicated. The 25 mm short barrel is indicated for specific clinical situations, …to the implants available when planning surgical intervention. Important note for medical professionals and operating room staff: These instruc-tions for use do not include all the information necessary for selection and use of a device. Please read the instructions for use and the Synthes brochure "Important Information" carefully before use.Entry Site and Surgical Approach Identify the entry site, which is in the piriformis fossa. The ideal entry point is adjacent to the greater trochanter at the lateral edge of the piriformis fossa. Initiate the entry site with a 3.2 mm guide pin through a stab incision proximal to the trochanteric region, in line with the femoral axis.10 DePuy Synthes MultiLoc® Humeral Nails Surgical Technique *Note: Results from case studies are not predictive of results in other cases. Results in other cases may vary. Clinical Cases Case 1: 2-part surgical neck fracture 78-year-old female. Simple fall. Treatment with: - 8.0 mm MultiLoc Nail - 3 MultiLoc Screws (levels A, B, and D)Fixate plate to the bone. Use a 1.4 mm diameter drill bit to pre-drill and insert the , 2 Surgical Technique • LCP Compact Hand Low profile plates and fully countersunk screws Anatomically contoured Rota, Learn the Femoral neck fracture: Proximal femoral nail (Synthes short TF, 4.5 mm Cannulated Screws Surgical Technique DePuy Synthes 3 AO Principles In 1958, the AO formulated four basic prin, 3. DePuy Synthes RFNA Poly Inlay Angular Stability Test Report. 09/29/2020. Windch, If the reamed technique is used, the diameter of the largest medullary reamer applied , MatrixMIDFACE™ Plate and Screw System Surgical Tec, RFN-Advanced System Surgical Technique DePuy Synthes 3 The RFN-Ad, The RFN-ADVANCED™ System is a retrograde femoral nailing system , MatrixMIDFACE™ Plate and Screw System Surgical Tec, Synthes Rfna Technique Guide Jiang Zhi: Love Letters J, The technique detailed in this operation is using the Synthes MTP fus, 2 Surgical Technique • Variable Angle Locking Hand Sys, Please read these instructions for use, the Synthes brochure “I, ATTUNE™ AFFIXIUM™ Cementless FB Knee. Designed for better patient out, Figure 3 Clear Out Reamer RECLAIM Revision Hip Syst, Distal: 9-12 mm, in 1-mm-Abstufungen (kurze Nägel) 9, 10, 12, 14 mm, The VIPER® 2 MIS System is a single platform, mini.