Synthes tfna inventory

02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.

INVENTORY CONTROL FORM Titanium Cannulated Trochanteric Fixation Nail System Implants (cont’d) Titanium Cannulated Trochanteric Fixation Nails, 12 mm distal diameter, sterile FEMORAL RIGHT LEFT LENGTH NECK ANGLE 456.450S 456.451S 300 125° 456.452S 456.453S 320 125° 456.454S 456.455S 340 125° 456.456S 456.457S 360 125° 456.458S 456.459S ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9514-C 9/12 Inventory Control Form 1.5 mm LCP Modular Mini Fragment System 1.5 mm Locking Screws, self-tapping, with T4 Stardrive recess LENGTH LENGTH 02.214.006 6 mm 02.214.007 7 mm 02.214.008 ...Fill synthes tfna inventory sheet : Try Risk Free. Rate free tfna inventory control form. 4.0. Satisfied. 57 Votes. For pdfFiller’s FAQs. Below is a list of the ...

Did you know?

The treatment of extra-capsular proximal femoral fractures remains challenging. In spite of a myriad of implant options that are available to the orthopaedic surgeon, complication rates ranging from 5 to 14% for fixation of peri-trochanteric fractures are still quoted in recent literature [1,2,3,4,5,6,7].The Trochanteric Fixation Nail …Apr 18, 2022 · The Synthes TFNA system offers both solid and fenestrated helical blade and lag screw options. The fenestrated head elements allow for cement augmentation. There is some evidence that augmented fixation may have a lower rate of failure in osteoporotic individuals, however evidence demonstrating superiority of cement augmentation in individuals ...SE_793148 AD page 2 / 8 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°

Inventory Control Form. 2.7 mm VA Locking Patella Plating System . Stainless Steel (316L) Patella Plates 2.7 mm Variable Angle Locking Screws, Non-Sterile, (10-60 mm), Stainless Steel . Anterior Patella Plate, core, small, sterile Anterior Patella Plate, 3-hole, small, sterile Anterior Patella Plate, 6-hole, small, sterileDESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.1. DePuy Synthes Biomechanical Evaluation of Non-Augmented & Augmented TFNA Head Elements in Surrogate Femoral Heads. December 5, 2019. Windchill #0000268245. † 2. Hofmann L, Zderic I, Hagen J, Agarwal Y, Scherrer S, Weber A, Altmann M, Windolf M, Gueorguiev B. Biomechanical effect of bone cement augmentation on thePlease contact your sales consultant for items approved for sale in Canada. VALCPDISRADPLATICF001 04/22. Open the catalog to page 1. Inventory Control Form Variable Angle LCP Distal Radius Plates Implants (cont'd) 2.4 mm VA LCP Volar Rim Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column 02.115.630 02.115.631 ...

4 DePuy Synthes Femoral Recon Nail System (FRN) Surgical Technique The Femoral Recon Nail System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration, or image artifact in the MR environment. The safety of Femoral Recon Nail System in the MR environment is …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10491-C 7/12 Inventory Control Form MultiLoc Humeral Nailing System 8.0 mm Titanium MultiLoc Proximal Humeral Nail, Cannulated, 160 mm, Sterile 04.016.034S Right 160 mm 04.016.035S Left 160 mmDistal: 9-12 mm, in 1-mm-Abstufungen (kurze Nägel) 9, 10, 12, 14 mm (lange Nägel) Kurze Nägel: 170 mm extrakurz 200 mm kurz 240 mm (ein Nagel passend für links und rechts) Lange Nägel: 300 mm-420 mm (linke und rechte Nägel, in 20-mm-Abstufungen) CCD-Winkel 125° und 130° Zusätzlich 135° für Nägel, Länge 240 mm.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes manufactures surgical instruments i. Possible cause: Introduction The recently developed femoral nec...

Femoral Neck System. The Femoral Neck System (FNS) is engineered for femoral neck fractures.1. Regardless of construct size, FNS offers enhanced rotational stability. Mechanical testing indicates up to 40% increased rotational stability when comparing to a sliding hip screw (SHS).2,4. Get in Touch with a Sales Consultant.Synthes Tfna Inventory 7434-9176 Form Apply a synthes tfna inventory 8664 template to doing choose download workflow more streamlined. Get Form. Show details Hide details How information works. Open form follow the ...Introduction The aim of this study was to evaluate the clinical and radiological outcomes of patients treated with the TFN-Advanced™ Proximal Femoral Nailing system (TFNA¸ DePuy Synthes, West Chester, PA) including intra- and postoperative complications. Materials and methods All patients with an acute proximal femur fracture …

The treatment of extra-capsular proximal femoral fractures remains challenging. In spite of a myriad of implant options that are available to the orthopaedic surgeon, complication rates ranging from 5 to 14% for fixation of peri-trochanteric fractures are still quoted in recent literature [1,2,3,4,5,6,7].The Trochanteric Fixation Nail …TFN-ADVANCED™ Implant only. ON. Static / Rotational Locking. ON. Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. visualized by pixelmolkerei.ch. Interactive 3D Web application by pixelmolkerei.6. DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill Document #0000302371 7. DePuy Synthes RFNA Nail/LAW Static Construct Design Verification Report. 08/08/2022. Windchill Document #0000293480 8. DePuy Synthes, RFN-Advanced System Nail TKA Fit Rationale. 09/30/2020. Windchill Document #0000302370 9.

free doordash codes for existing users Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ... pollen count fitchburg ma2k23 demi god build Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESSynthes TFNA FENESTRATED SCREW 80 mm Condition: Used 04.038.180 Synthes TFNA FENESTRATED SCREW 80 mm. $270.00 Add to Cart ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 240-050-988 Stryker SDC Ultra™ Image Management System ... gully in arid climate crossword clue 3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 10 holes, 177 mm, right saxonburg gun bashtj ott and marissa mclaughlinkumbomb on newgrounds 1. DePuy Synthes Biomechanical Evaluation of Non-Augmented & Augmented TFNA Head Elements in Surrogate Femoral Heads. December 5, 2019. Windchill #0000268245. † 2. Hofmann L, Zderic I, Hagen J, Agarwal Y, Scherrer S, Weber A, Altmann M, Windolf M, Gueorguiev B. Biomechanical effect of bone cement augmentation on the how much is a four wheel alignment at walmart INVENTORY CONTROL FORM Titanium Cannulated Trochanteric Fixation Nail System Implants (cont’d) Titanium Cannulated Trochanteric Fixation Nails, 12 mm distal …SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ... philadelphia derringer kitwow wellpath loginwalgreens prescription in progress Inventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 ...Introduction The aim of this study was to evaluate the clinical and radiological outcomes of patients treated with the TFN-Advanced™ Proximal Femoral Nailing system (TFNA¸ DePuy Synthes, West Chester, PA) including intra- and postoperative complications. Materials and methods All patients with an acute proximal femur fracture consequently treated with a TFNA between September 2014 and ...